引用本文: | 高景明,刘永贵,杨建华,等.基于金属膜电阻的大功率低电感负载.[J].国防科技大学学报,2009,31(1):43-46.[点击复制] |
GAO Jingming,LIU Yonggui,YANG Jianhua,et al.High Power Low Inductance Dummy Load Made of Metal Film Resistors[J].Journal of National University of Defense Technology,2009,31(1):43-46[点击复制] |
|
|
|
本文已被:浏览 7525次 下载 6130次 |
基于金属膜电阻的大功率低电感负载 |
高景明, 刘永贵, 杨建华, 周相, 龙霞锋 |
(国防科技大学 光电科学与工程学院,湖南 长沙 410073)
|
摘要: |
利用金属膜电阻设计并制作了用于陡化前沿Marx发生器调试的大功率低电感负载。其阻值约为90Ω,电感约为55nH,基本不具备分散电容。该负载采用线性渐变的圆锥外型结构,有利于减小信号在负载上的反射,配合电容分压器使用能够很好地完成对前沿约为几ns的快前沿高压脉冲的测量。理论估算了该负载的功率容量,并利用PSpice软件模拟了对其进行脉冲方波加载的情况。该负载用于调试陡化前沿的Marx发生器的实验中,获得了幅值约210kV,脉宽近40ns,前沿为5ns的快前沿高压脉冲。多次实验结果表明该负载性能稳定,适用于陡化前沿Marx发生器的调试工作。 |
关键词: 大功率低电感负载 陡化前沿Marx发生器 快前沿高压脉冲 测量 |
DOI: |
投稿日期:2008-05-23 |
基金项目:国家高技术发展计划项目 |
|
High Power Low Inductance Dummy Load Made of Metal Film Resistors |
GAO Jingming, LIU Yonggui, YANG Jianhua, ZHOU Xiang, LONG Xiafeng |
(College of Opto-electronic Science and Engineering, National Univ. of Defense Technology, Changsha 410073, China)
|
Abstract: |
This paper presents a high power low inductance dummy load made of metal film resistors, of which the resistance is 90Ω,and the inductance is ~55nH, nearly without stray capacitance. Cooperated with a capacitive divider, the dummy load has been utilized to measure high voltage pulse with a rise time of several ns for testing a 10-stage wave erection Marx generator. Experimental results verify the high performance of this load, compared with a water resistor load of the same resistance. This high performance is determined by two virtues in the design: one is for using non-capacitance of the metal film resistors and the other is for adopting a structure of impedance tapering line. Power tolerance of the load is evaluated theoretically. In addition, the response ability fed by a square voltage wave is simulated by PSpice software. The dummy load has been tested on the wave erection Marx generator, producing a high voltage pulse with an amplitude of ~210kV, a pulse width of ~40ns and a rise time of ~5ns, and long term operations show its high reliability and stability. |
Keywords: dummy load of high power capability and low inductance wave erection marx generator fast rise time high voltage pulse measurement |
|
|
|
|
|