    摘要:

    文中解决了 100 升卧式混合机搅拌固体推进剂药浆的温度远距离自动测量的技术关键——测温点的选择和测温头外形、尺寸及安装结构的确定,从而实现了药浆搅拌温度的自动测量。本文还对涮温头插入误差作了计算。

    Abstract:

    This paper introduces the key technique used for remote automatic measurements of temperatures of solid-propellant pulps being agitated in a horizontal mixer of the size 100 liters,inc1uding selection of measurement points,definition of measurement head appearances and sizes and installation structures,so that a complete automatic measurement of temperation of medical pulps agitated with a mixer can be implemented. In addition,the calculation of insertion errors of measurement heads is presented in the paper.