    The study of pulse transformer is one of the key problems of pulsed power conditioning system.The technical requirement and the construction parameters of the pulse transformer are presented.Test results of the transformer are also given.The inductance of the primary coil is 3.6μH,and the coupling efficiency is 0.77.When input voltage is 60kV,output voltage can be 500kV.