    In order to find out the cause of position deviation of the roller mechanism, the interference source is determined by comparing the feedback signals and making position test at different situations. Based on analysis of the reason that the feedback signals are interfered, several measures are adopted and their effects are given. In the end, the problem is solved by using an isolation transformer for Y-axis driver. It is shown that this solution has good effects in wind tunnel test.