Performance analysis of the moving primary six-phase linear induction motor
CSTR:
Author:
Affiliation:

Clc Number:

TM359

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    In order to accurately describe the object model, the first-order equivalent circuit transient eddy current analysis method was used to quantitatively calculate the parameter time-varying rule of the moving primary high-speed six-phase linear induction motor under the influence of the dynamic end effect, and the equivalent circuit of the motor was deduced considering the dynamic end effect through the deduce of the induction eddy current loss. On this basis, the performance characteristics of the motor under the influence of the dynamic end effect were analyzed in detail through the calculation of electromagnetic thrust and efficiency evaluation. The correctness of the theoretical analysis and the accuracy of the motor model were verified by the finite element simulation and dynamic experiment under different operating speeds.

    Reference
    Related
    Cited by
Get Citation
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:December 20,2019
  • Revised:
  • Adopted:
  • Online: July 20,2021
  • Published: August 28,2021
Article QR Code