通气空泡与超音速尾喷流耦合作用实验研究
作者:
作者单位:

(国防科技大学 空天科学学院, 湖南 长沙 410073)

作者简介:

赵小宇(1989—),男,湖南常德人,博士研究生,E-mail:zhaoxiaoyu14@nudt.edu.cn; 向敏(通信作者),女,副研究员,博士,硕士生导师,E-mail:xiangmin333@hotmail.com

通讯作者:

中图分类号:

O359+.1

基金项目:

国家自然科学基金资助项目(51776221);国防科技大学校科研基金资助项目(ZK18-02-07)


Experimental study on the coupling effect of ventilated cavity and supersonic tail jet
Author:
Affiliation:

(College of Aerospace Science and Engineering, National University of Defense Technology, Changsha 410073, China)

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    基于开放式水洞,构建了通气空泡与超音速尾喷流耦合作用实验系统。设计了四种可变长度实验模型,重点研究射流与通气空泡相对位置对空泡射流耦合作用机理的影响。针对不同外形实验模型,改变通气流量和射流流量,获得了不同工况下空泡界面瞬态演化规律。通过实验,观察到射流完全补气、射流部分泄气、射流完全泄气三种不同耦合作用模式。进一步结合实验数据和Paryshev理论分析,建立了不同模式下临界转变条件和空泡尺度计算模型。当J≤0.1 时,空泡长度可用经典空泡经验公式来描述;当0.1<J<1.5 时,空泡长度分为模型长度和尾部空泡长度两部分,而尾部空泡长度只与无量纲动量比J有关;当 J≥1.5时,空泡闭合在喷管出口,空泡长度与模型长度相等。

    Abstract:

    Based on an open water tunnel, an experimental system for the coupling of ventilated cavity and supersonic jets was constructed. Four variable length experimental models were designed, focusing on the influence of the relative position of the jet and the ventilated cavity on the interaction mechanism. For different experimental models, the ventilation flow and jet flow were changed to obtain the dynamic process of the evolution of the cavity interface under different working conditions. Experiment observed three distinct mechanisms, which were divided into the following types:the jet fully inflated the cavity and the jet partially deflated the cavity; the jet fully deflated the cavity. By combining the experimental results and Paryshev′s theory, the calculation model of the cavity size and critical transition conditions for different mechanism were further constructed. When J≤0.1, the cavitation length can be described by the classic cavity empirical formula; When 0.1<J<1.5, the cavitation length is divided into two parts:the model length and the tail cavity length, and the length of the closed cavity from the nozzle outlet is only related to the parameter J; When J≥1.5, the ventilated cavity closes at the tail of the nozzle, the cavity length is approximately equal to the model length.

    参考文献
    相似文献
    引证文献
引用本文

赵小宇,向敏,刘波,等.通气空泡与超音速尾喷流耦合作用实验研究[J].国防科技大学学报,2021,43(5):53-60.
ZHAO Xiaoyu, XIANG Min, LIU Bo, et al. Experimental study on the coupling effect of ventilated cavity and supersonic tail jet[J]. Journal of National University of Defense Technology,2021,43(5):53-60.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2021-04-06
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2021-09-29
  • 出版日期: 2021-10-28
文章二维码