微机械陀螺品质因数的在线测量方法 |
王安成, 胡小平, 罗兵, 王谱华 |
(国防科技大学 机电工程与自动化学院, 湖南 长沙 410073)
|
摘要: |
品质因数是决定微机械陀螺结构性能的重要参数。传统测量振动结构品质因数的幅频曲线半功率带宽法需要记录大量幅频响应数据并需作离线处理,测量效率很低。通过分析微机械陀螺动力学模型发现,品质因数可根据谐振频率及相频函数在谐振频率点处的一阶导数值计算,且相频曲线在谐振频率点附近近似为线性。利用这些特点,提出一种新的品质因数在线快速测量方法。首先,在谐振频率附近对陀螺进行激励,得到相频数据;然后,使用递推最小二乘法估计出相频曲线斜率;最后根据该斜率和谐振频率值计算出品质因数。新方法不需要存储和离线分析频率响应数据,可以自动确定品质因数。仿真和实验验证了本文方法的正确性和可行性。 |
关键词: 微机械陀螺 品质因数 相频曲线 在线测量 |
DOI:10.11887/j.cn.201403013 |
投稿日期:2013-09-11 |
基金项目:湖南省研究生科研创新资助项目(CX2012B014);国防科技大学优秀研究生创新资助项目(4345111141N) |
|
On-line measurement for the quality factor of the micro-machined gyroscope |
WANG Ancheng, HU Xiaoping, LUO Bing, WANG Puhua |
(College of Mechatronics Engineering and Automation, National University of Defense Technology, Changsha 410073, China)
|
Abstract: |
Quality factor is a key parameter determining the performance of the micro-machined gyroscope. The conventional measurement, the half-power bandwidth method, is low in efficiency, since it requires the user to store and deal with a multitude of amplitude-frequency response data. Based on the analyses on the dynamics model, the quality factor can be calculated according to the resonance frequency and first derivation of the phase-frequency function at the resonance frequency point, and the phase-frequency graph is approximately linear near the resonance point. Upon these characteristics, an online and quick quality factor measurement method was put forward. First, the gyroscope was excited near the resonance point to obtain the phase-frequency data. Then, the slope of the phase frequency was estimated by using the recursive least squares method. Finally, the quality factor was obtained according to the slope and the resonant frequency. The simulation and experimental results verify the correctness and feasibility of the proposed method. |
Keywords: micro-machined gyroscope quality factor phase-frequency graph on-line measurement |
|
|
|
|
|