A Research on the Measurement and Compensation of the Straightline Error Motion of an Ultra Precision Lathe
DOI:
CSTR:
Author:
Affiliation:
Clc Number:
Fund Project:
Article
|
Figures
|
Metrics
|
Reference
|
Related
|
Cited by
|
Materials
|
Comments
Abstract:
This paper discusses the 3-point error separating technique for on-line measurement of straight line error motion of an ultra-precision lathe and straightness of the generatrix of turned works. The accuracy of the measuring system is obtained about 土0.078μm (土3σ). Furthermore,a closed loop,micro-computer control system is built up to process the error data and excite a servo-mechanism for Compen sating the error motion,and the straightness of the turned work is increased to 0.5μm/160mm,that is,Compensating increases straightness by 50%,at least than before compensating.