A time-domain worst-case noise algorithm for power delivery network with non-zero current transition times
CSTR:
Author:
Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    With the increasing of clock frequency and the decreasing of supply voltage, power integrity becomes a critical issue. The effect of the transition time of load currents was taken into account, and a more realistic worst-case noise prediction was obtained. In addition, a dynamic programming algorithm is introduced for the time-domain impulse response of the power distribution system, and a modified Knuth-Yao quadrangle inequality speedup method is developed which reduces the time complexity of the algorithm from O(n2m) to O(mnlogn).